Background

Impaired coronary blood flow may contribute to abnormalities in left ventricular relaxation and filling, even in the absence of overt systolic dysfunction. TIMI frame count (TFC) provides a simple and objective quantitative assessment of coronary blood flow during coronary angiography. This study aimed to investigate the relationship between TFC and left ventricular diastolic function in patients undergoing coronary angiography.

Methods 

This observational cross-sectional study included 85 patients undergoing coronary angiography at Mansoura University Hospitals between September 2025 and June 2026. Coronary blood flow was quantitatively assessed using the TIMI frame count (TFC) method, with corrected TFC applied to the left anterior descending artery. Transthoracic echocardiography was performed within 24 hours before or after coronary angiography to assess left ventricular systolic and diastolic function using conventional Doppler and tissue Doppler parameters. Left ventricular diastolic function was categorized using an integrated assessment of the available conventional Doppler and tissue Doppler parameters into four study-defined filling-pattern groups.

Results 

Mean TFC differed significantly across the four study-defined diastolic-function groups (Kruskal–Wallis H = 71.98, P < 0.001; ε² = 0.852, bootstrap 95% CI 0.707–0.926), increasing from a median (IQR) of 25.67 (25.08–26.00) frames in Group 1 to 42.67 (41.08–44.25) frames in Group 4. Mean TFC showed strong correlations with key diastolic parameters, including septal E/e′ (r = 0.822, P < 0.001) and lateral e′ (r = −0.764, P < 0.001). In multivariable analysis, septal E/e′, lateral e′, and LA diameter were independently associated with mean TFC (adjusted R² = 0.831, P < 0.001). Exploratory ROC analysis demonstrated excellent discrimination between study-defined Groups 3–4 and Groups 1–2, with an AUC of 0.990 (95% CI 0.970–1.000). At the optimal cutoff of ≥34.3 frames, sensitivity was 100% and specificity was 98.2%.

Conclusion 

TIMI frame count was significantly associated with less favorable echocardiographic indices and study-defined filling patterns of left ventricular diastolic function. These findings demonstrate an association between delayed coronary contrast progression and LV functional impairment but do not establish TFC as a diagnostic marker of diastolic dysfunction. Further prospective studies are warranted to validate its clinical utility.

Creative Commons License

Creative Commons Attribution 4.0 International License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Share

COinS